<Error>
<ErrorNumber>17676</ErrorNumber>
<ErrorFamily>Exposure Head</ErrorFamily>
<ErrorMessage>
HEAD: EH-PHI cbl. (hotlink fault)
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Thermal</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
If this error occurs in the field, chances are that the cable is
faulty.
</text></DescriptionText>
<DescriptionText><text>
Note that this error can be masked off by using the HEAD MASK command.
Note that this is not recommded action for field machines!
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Call service.
</text></DescriptionText>
</OperatorAction>
<Cause>
The EH-PHI cable is not properly connected between the exposure head
(EH) and Parallel Head Interface (PHI) board.
</Cause>
<Cause>
The EH-PHI cable connector is faulty.
</Cause>
<Cause>
The EH-PHI cable is faulty.
</Cause>
<Cause>
The cable from the PHI board to where the saom used to be 10-0793 is prone
to break at the PHI board end connector.  SMA barrel connector (cable to cable)
10-3560 is robust.
</Cause>
<Cause>
Few old heads have pigtails on head end of hotlink - wire may break inside head.
</Cause>
<SeeAlso>
<UnnumberedList>
Troubleshooting, thermal troubleshooting procedures 3.1 page 30
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:40 2008 PST
</Updated>
<Links>
</Links>
</Error>